<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">75504</journal-id>
      <journal-title-group>
        <journal-title>Magazine of Civil Engineering</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Magazine of Civil Engineering</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2712-8172</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">6</article-id>
      <article-id pub-id-type="doi">10.18720/MCE.19.7</article-id>
      <title-group>
        <article-title>Influence of the physicotechnical and geometrical characteristics of plastering covering on moisture conditions of AAC-blocks homogeneous walls</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Влияние физико-технических и геометрических характеристик штукатурных покрытий на влажностный режим однородных стен из газобетонных блоков</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">0000-0002-1196-8004</contrib-id>
          <contrib-id contrib-id-type="scopus">6508103761</contrib-id>
          <contrib-id contrib-id-type="researcherid">M-6585-2013</contrib-id>
          <name>
            <surname>Vatin</surname>
            <given-names>Nikolai</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>vatin@mail.ru</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Glumov</surname>
            <given-names>A.</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <contrib contrib-type="author">
          <contrib-id contrib-id-type="orcid">http://orcid.org/0000-0003-3251-3356</contrib-id>
          <contrib-id contrib-id-type="scopus">15730895100</contrib-id>
          <name>
            <surname>Gorshkov</surname>
            <given-names>Alexander</given-names>
          </name>
          <xref ref-type="aff" rid="aff3"/>
          <email>alsgor@yandex.ru</email>
        </contrib>
      </contrib-group>
      <aff id="aff1">Peter the Great Saint Petersburg Polytechnic University</aff>
      <aff id="aff2">«H+H» Ltd</aff>
      <aff id="aff3">Saint Petersburg State University of Industrial Technologies and Design</aff>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2011-02-20">
        <day>20</day>
        <month>02</month>
        <year>2011</year>
      </pub-date>
      <issue>1</issue>
      <issue-id pub-id-type="publisher-id">19</issue-id>
      <fpage>28</fpage>
      <lpage>33</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://engstroy.spbstu.ru/userfiles/files/2011/1(19)/gorshkov_vlazhnost'.pdf"/>
      <abstract xml:lang="en">
        <p>The article presents the technical analysis of the structure and physical characteristics influence of various plastering coverings on on moisture conditions of  AAC-blocks homogeneous walls. The diagrams of partial (maximum and actual) pressure distributions of water steam along the thickness of the tested homogeneous outside walls are provided. Calculations and diagrams were done for both the coldest month of the year and the coldest five-days period, i.e. under the worst climate conditions. The essential patterns of the influence of plastering covering charactristics (thickness, density, vapor permiability coefficient) on humidity accumulation processes in walls are determined. Practical recommendations for finishing of AAC-blocks  walls to protect them from excessive moistening can also be found in the research.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>vapor permeabilty</kwd>
        <kwd>walling of buildings</kwd>
        <kwd>plaster</kwd>
        <kwd>moisture conditions</kwd>
        <kwd>aerated concrete</kwd>
        <kwd>thermal protection</kwd>
      </kwd-group>