<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="ru">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">75504</journal-id>
      <journal-title-group>
        <journal-title>Magazine of Civil Engineering</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Magazine of Civil Engineering</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2712-8172</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">7</article-id>
      <article-id pub-id-type="doi">10.5862/MCE.32.7</article-id>
      <title-group>
        <article-title>The methodology of corona air ionizer usage when correcting the indoor air ion composition</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Методологический подход к применению коронных аэроионизаторов при проведении коррекции аэроионного состава воздуха помещений</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Chernyi</surname>
            <given-names>K.</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>chernyy_k@mail.ru</email>
        </contrib>
      </contrib-group>
      <aff id="aff1">Perm National Research Polytechnic University</aff>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2012-10-20">
        <day>20</day>
        <month>10</month>
        <year>2012</year>
      </pub-date>
      <issue>6</issue>
      <issue-id pub-id-type="publisher-id">32</issue-id>
      <fpage>48</fpage>
      <lpage>53</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://engstroy.spbstu.ru/userfiles/files/2012/6(32)/07.pdf"/>
      <abstract xml:lang="en">
        <p>There is a need of the solution of two inconsistent tasks connected with features of technical characteristics assignment when using electrical corona air ionizers for correction of air ion composition. On the one hand, for providing sufficient generating ability of the air ionizer the increasing of corona voltage is necessary. On the other hand, increase of the corona voltage leads to increasing in generation of concomitant harmful chemical compounds. Results of research of small air ion concentration and volume concentration of ozone O3, nitrogen oxide NO and nitrogen oxides (in terms of NO2) are presented. The received empirical dependences allow to carry out calculating of change of foregoing above characteristics for formed air ion composition.</p>
      </abstract>
      <kwd-group xml:lang="en">
        <kwd>corona air ionizer</kwd>
        <kwd>small air ion</kwd>
        <kwd>corona discharge</kwd>
      </kwd-group>
    </article-meta>
  </front>
</article>
