<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "https://jats.nlm.nih.gov/publishing/1.3/JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front xmlns:xlink="http://www.w3.org/1999/xlink">
    <journal-meta>
      <journal-id journal-id-type="elibrary">75504</journal-id>
      <journal-title-group>
        <journal-title>Magazine of Civil Engineering</journal-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Magazine of Civil Engineering</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2712-8172</issn>
    </journal-meta>
    <article-meta xmlns:xlink="http://www.w3.org/1999/xlink">
      <article-id pub-id-type="publisher-id">2</article-id>
      <article-id pub-id-type="doi">10.5862/MCE.34.2</article-id>
      <title-group>
        <article-title>Risk evaluation of composite heat insulation fasade systems installation in the conditions of diurnal temperature variations under +5°C</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Оценка рисков устройства фасадных теплоизоляционных композиционных систем при суточных колебаниях температуры воздуха ниже +5°C</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Pashkevich</surname>
            <given-names>Stanislav</given-names>
          </name>
          <xref ref-type="aff" rid="aff1"/>
          <email>pashkevich86@mail.ru</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Pustovgar</surname>
            <given-names>Andrey</given-names>
          </name>
          <xref ref-type="aff" rid="aff2"/>
          <email>nsm.mgsu@mail.ru</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Adamtsevich</surname>
            <given-names>Aleksey</given-names>
          </name>
          <xref ref-type="aff" rid="aff3"/>
          <email>MnSpecter@gmail.com</email>
        </contrib>
      </contrib-group>
      <aff id="aff1">Moscow State Building University</aff>
      <aff id="aff2">National Research Moscow State Civil Engineering University</aff>
      <aff id="aff3">Moscow State University of Civil Engineering</aff>
      <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2012-12-25">
        <day>25</day>
        <month>12</month>
        <year>2012</year>
      </pub-date>
      <issue>8</issue>
      <issue-id pub-id-type="publisher-id">34</issue-id>
      <fpage>15</fpage>
      <lpage>21</lpage>
      <self-uri xmlns:xlink="http://www.w3.org/1999/xlink" content-type="pdf" xlink:href="https://engstroy.spbstu.ru/userfiles/files/2012/8(34)/02.pdf"/>
      <abstract xml:lang="en">
        <p>Allowable temperature conditions for hydration processes of the majority hydraulic binders are in the range (+5... +30)°C. That is why temperature is important for work with ETICS - external thermal insulation composite systems. Period with an average daily outdoor temperature +5°C is quite arbitrary, because temperature can drop below the limit value in the night and unpredictable frosts promote the risk of slowdown (or termination) of hydration processes of hydraulic binders in the fresh plaster. For the qualitative risk assessment of the operational properties reduction for plaster layers of walling, in this paper a full-scale laboratory simulation of the production of ETICS in conditions of unstable diurnal fluctuations in air temperature was conducted using a mobile stand for facades trials. According to the test results, a significant degradation in major performance in the case of daily fluctuations in air temperature below +5°C was determined.</p>
      </abstract>